For economical sound control with design flexibility and ease of installation in large environments, Ceiling Baffles is a proven solution. Not only are our Baffles functional, they add an appealing architectural element to any new construction or retrofit installation. Available in single (Type I) and double (Type II) styles in a full range of fabric and vinyl coverings to complement new or existing décor. Custom sizes and shapes are also 

 

Thickness Finish Core Absorption Coefficients
(Inches)     125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC
Type I
1 Fabric Glass Fiber 4.55 6.20 8.42 12.83 14.35 14.28 N/A

 

Two pieces of lightweight 7PCF glass fiber core with square or radius edges and corners; covered with perforated vinyl or fabric.      Mounting: Has D-rings installed on baffle for easy and secure hanging from ceiling.      Thickness: 1″, 2″      NRC Chart  

Thickness Finish Core Absorption Coefficients
(Inches)     125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC
Type II
2 Fabric Glass Fiber 4.48 8.00 13.20 17.93 16.98 16.35 N/A

In order to further reduce reflective sound, baffles can be suspended from the ceiling. Colors and fabric selections are the same as those for the wall panels to fit with the overall design.  

TYPE I BAFFLE

  Type I Baffles are comprised of one piece of a light weight, 7 PCF glass fiber core, covered on all faces and edges with a fabric finish. They can have square or radius edges and corners, and can be utilized for additional sound absorption in existing spaces. Mounting is with D-ring.      Thicknesses:  1″, 2″.      Absorption Rating: 1″ x 48″ x 12″ — 6.4 sabins.      

A. SCOPE      This section includes all of the Type 1 Acoustical Baffles as manufactured by Custom Acoustical Products  

B. MATERIALS

 

     
  1. Type 1 Acoustical Baffles shall be constructed of one piece of 7 PCF noncombustible and dimensionally stable glass fiber core. Each one piece unit shall be (1″),  (2″) in thickness and in height and width as required. All edges shall have internal edge protection. The edges of the baffle shall be (square), (radius) and corners (square), (radius).
  2.  

  3. The faces and all edges shall be covered with (nonwoven or woven polyester fabric), (manufacturer approved custom fabric).
  4.  

  5. The Type 1 Acoustical Baffles shall have a Noise Reduction Coefficient of 1.5 sabins / sq. ft. (2″) using ASTM C423-81a, Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method.
  6.  

  C. JOB CONDITIONS  

     
  1. Installation of Type 1 Acoustical Baffles shall not begin until all wet work, such as plastering, concrete, etc. is completely dry. The baffles are designed for installation under standard occupancy conditions from 60ºF to 85‚¬F and not more than 80% R.H. in an enclosed building.
  2.  

  3. The contractor shall be responsible for the examination and acceptance of all surfaces and conditions prior to baffle installation.
  4.  

  D. INSTALLATION  

     
  1. All Type 1 Acoustical Baffles should be installed in accordance with the manufacturer”s specifications and recommendations.
  2.  

  3. All necessary hardware and accessories for the complete job installation are to be furnished by the contractor.
  4.  

 

TYPE II BAFFLE

  The core of the Type II Baffle is made up of two pieces of glass fiber. Faces and edges can either have square or radius edges and corners, and may be covered with perforated vinyl or fabric. Applications would be for additional sound absorption. Mounting is with D-Rings.      Thicknesses: 1″,  2″.      Absorption Rating: 2″ x 48″ x 24″ — 12 sabins.      

A. SCOPE      This section includes all of the Acoustical Baffels by Custom Acoustical Products      

B. MATERIALS    

     
  1. Type 2 Baffles shall be constructed of two pieces of 7 PCF non-combustible and dimensional stable glass fiber core. Each one piece unit shall be (1″),  (2″) in thickness and in height and width as required. All edges shall have internal edge protection. The edges of the baffle shall be (square), (radius) and corners (square), (radius).
  2.  

  3. The face and all edges shall be covered with (nonwoven or woven polyester fabric), (perforated vinyl), (manufacturer approved custom fabric).
  4.  

  5. Type 2 Ceiling Baffles shall have a Noise Reduction Coefficient of 1.5 sabins/sq. ft. (2″) using ASTM C423-81a, Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method.
  6.  

  C. JOB CONDITIONS    

     
  1. Installation of Type 2 Ceiling Baffles shall not begin until all wet work, such as plastering, concrete, etc. is completely dry. The baffles are designed for installation under standard occupancy conditions from 60ºF to 85ºF and not more than 80% R.H. in an enclosed building.
  2.  

  3. The contractor shall be responsible for the examination and acceptance of all surfaces and conditions prior to baffle installation.
  4.  

  D. INSTALLATION  

     
  1. All Type 2 Ceiling Baffles should be installed in accordance with the manufacturer”s specifications and recommendations.
  2.  

  3. All necessary hardware and accessories for the complete job installation are to be furnished by the contractor.